NIST traceable colour transmission calibration slide - calibrated

Microscopy colour patches to gauge colour accuracy. NIST traceable calibration data for each large colour patch is provided as spectral transmission. This information can be converted to the colour space you need by using the supported spreadsheet (such as Adobe RGB 1998, L*A*B *, XYZ etc.).24 colour patches plus large clear areaBlack background to minimise flareThe 4150 µm diameter patches are individually calibrated for spectral transmission. This allows accurate conversion (using the supplied spreadsheet) to other colour space units.Smaller patches from 1,000 µm diameter to 150 µm diameter are exposed and processed at the same time produce good correlation of the large calibrated patches to the smaller ones, but are not calibrated.Oil immersion objectives can be used because a standard 0.15 mm glass cover slip is permanently cemented...

Microscopy colour patches to gauge colour accuracy. NIST traceable calibration data for each large colour patch is provided as spectral transmission. This information can be converted to the colour space you need by using the supported spreadsheet (such as Adobe RGB 1998, L*A*B *, XYZ etc.).

  • 24 colour patches plus large clear area
  • Black background to minimise flare
  • The 4150 µm diameter patches are individually calibrated for spectral transmission. This allows accurate conversion (using the supplied spreadsheet) to other colour space units.
  • Smaller patches from 1,000 µm diameter to 150 µm diameter are exposed and processed at the same time produce good correlation of the large calibrated patches to the smaller ones, but are not calibrated.
  • Oil immersion objectives can be used because a standard 0.15 mm glass cover slip is permanently cemented over the colour film.
  • Film is permanently sandwiched between glass; atmospheric deterioration of the measured values is minimized.
  • Each slide is individually serialized and calibrated.

Specifications

Overall Size 75mm x 25mm
Feature Array 24 unique colour patches in 9 different sizes, ranging from 4.150 mm diameter to 0.150 mm diameter, and a large clear film area. Only the large patches (and clear area) are directly calibrated, but all patches are imaged and processed at the same time.
Polarity Negative
Material 0.2 mm (0.007") thick polyester photo-film mounted onto 0.9 to 1 mm water white Soda-lime glass with a 0.15 mm (0.006") glass coverslip for protection (exact thickness is subject to change)

Includes

  • Calibrated IAM-9C colour microscope slide
  • Calibration Certificate
  • Calibration Data Report
  • Conversion Spreadsheet
  • USB flash drive with data and spreadsheet
  • Protective case
Code Title Pack Size Availability Price Updated: 05-03-2024
EMS79504 NIST traceable colour transmission calibration slide - calibrated Each 2 weeks Quote only Quote
Quote