Vibrating microtome, 115V or 220V
This new entry level microtome is perfect for techniques such as histology, organotype slice culture and low resolution imaging with a fixed blade holder and a mechanism Z-axis error rate of 5-8µm. The 5100mz-Plus and 5100mz are very competitively priced high precision units with a Z-axis deflection of only 1-2 microns and a blade advance controllable to 10 microns/sec. On all units the section thickness step size is 0.001mm. The 7000smz-2 and 5100mz-Plus are supplied with their own Z-axis calibration verifier.
Model 5100mz - Vibrating Microtome, includes demountable tissue bath and sample blades in stainless steel and ceramic. 115V or 220V
Model 5100mz-Plus - Vibrating Microtome, includes demountable tissue bath and sample blades in stainless steel and ceramic. 115V or 220V
Model 7000smz-2 - Programmable Vibrating Microtome, includes demountable tissue bath and sample blades in stainless steel and ceramic, plus 'Opti-Cal' z-axis calibration device. 115V or 230V
Specifications | 7000smz-2 | 5100mz series |
Section thickness step size | 1µm | 1µm |
Vertical (Z-Axis) calibration device 'Opti-cal' is calibrated with metrology equipment traceable to National Standards |
'Opti-cal' included as standard | 'Opti-cal' included as standard for 5100mz-Plus Optional extra for 5100mz |
Optimal Z-axis Deflection | Sub-µm (± 0.1µm) | ≈ 5-8µm (2.0µm ± 0.1 with calibration upgrade kit) |
Max specimen size | 33x50x19 | 33x50x19 |
Maximum (vertical) travel of bath table | 19mm | 19mm |
Memory to store section thickness | Yes | Yes |
Multiple user settings | 8 different | 8 different |
Cutting head advance speed while slicing | From a minimum of -1.00mm/sec, through zero to a maximum of +1.00mm/sec | From a minimum of -1.00mm/sec, through zero to a maximum of +1.00mm/sec |
Cutting head advance speed resolution while slicing | 0.01mm/sec | 0.10mm/sec |
Cutting head advance speed max (fast mode when not slicing) | +/- 4.0mm/sec | +/- 2.0mm/sec |
Specimen retraction as blade retracts | Yes | Yes |
Cutting head retraction speed (fast mode) | 4.0mm/sec | 2.0mm/sec |
Operating Modes | Manual, semi-auto 'slice window' or fully automated 'profile repeat' | Manual or semi-auto 'slice window' |
Blade oscillation frequency range (dependent on amplitude) | 50-120Hz | 50-80Hz |
Frequency step size | 5Hz | 5Hz |
Blade oscillation amplitude | Minimum: 0.5mm (nominal) Maximum: 2.5mm (nominal) |
Minimum: 0.5mm (nominal) Maximum: 1.5mm (nominal) |
Amplitude step size | 0.25mm (nominal) | 0.5mm (nominal) |
Cooling options | Ice bath or optional Model 7610A Tissue Bath Cooler | Ice bath or optional Model 7610A Tissue Bath Cooler |
Power requirements | 115VAC 60Hz or 230VAC 50Hz (selectable) |
90-264 VAC 50/60Hz (switch mode PSU) |
Power rating | 100W | 65W |
Fuse rating (115v or 230v) | T2A 250VAC | T2A 250VAC |
Light source | 100-240VAC 3W mains connection | Powered from 5100mz |
Dimensions | 420mm W x 400mm D x 270mm H (excluding light source and microscope) | 350mm W x 450mm D x 350mm H (excluding magnifier/light source) |
Weight | 35kg | 15kg |
Options
1. Temperature controlled standard tissue bath cooler - Model 7610-A
Product Description
The 7610-A tissue bath cooler Unit is intended for use with our 7000 and 5100 range of vibrating microtomes. Unfixed brain slices sectioned at 4°C give better tissue preservation and are viable for longer in-vitro recordings. Additionally, some enzyme histochemical techniques give better staining results when sectioned at low temperatures.
Tissue Bath Mount - Model 7610-A
The 7610 Series coolers use "Peltier" thermoelectric elements. The stainless steel tissue bath and mount are detachable to allow sterilization by autoclave if required. Tissue Bath Mount
The equipment comprises of a mains operated control unit, cooling element, tissue bath and specimen holder. The control unit houses a power supply and temperature control circuitry. The cooling element assembly consists of thermoelectric "Peltier" elements, temperature feedback sensors and a cold water fed heat exchanger.
Current from the power supply flows through the thermoelectric elements, which act as heat transfer units. Heat is drawn off, cooling the solution in the tissue bath. The heat generated by this process is removed by the water supply fed through the heat exchanger. The unit uses a proportional temperature control algorithm to maintain temperature stability. This will hold the bath temperature to within 0.5°C of the temperature set point. There will, however, be a small variation in temperature vertically through the bath. Experience will show the best temperature to be set for any given requirement and ambient temperature.
Product Specifications
Display Resolution: | 0.1°C |
Temperature Accuracy: | +/- .5°C |
*Temperature Range: | +8°C to 0°C |
Voltage Requirements: | 230V 50Hz or 115V 60Hz |
Power Rating: | 60W |
Inlet Fuse Rating: | 2A |
*Note that the actual temperatures achievable will be dependent upon the solutions used and local temperature conditions.
2. Integrally Mounted Cold Light Source - Model 7000-2-1
Product Description
To facilitate the careful slicing operation, it is most important that the progress of the blade through the tissue be clearly observed. This observation is used to ensure control of the speed of advance and of the oscillation of the blade. Two elements are required for clear observation, light and magnification.
![]() |
Model 7000-2-1 |
Product Features
- Ability to direct the light where needed with two flexible fiber optic light guides
- Maintains temperature stability of the tissue or surrounding a.c.s.f.
- Light Intensity is adjustable by a rotary dial knob
- 20W/12V Halogen lamp
- 2000 hour life approx
- Fan and electronic power supply
- Adjustable with potentiometer
- Twin 500mm fiber optic light guides
3. Integrally Mounted Magnifying Glass - Model 7000-1-3
Product Description
For general global slices a magnifying glass offering approx 2x magnification is sufficient. However, if specific loci are under study then an inspection microscope is desirable. The binocular inspection microscope with 10x-40x magnification, a zoom of 1x-4x and a working distance of 80mm is ideal for the task.
![]() |
Model 7000-1-3 |
Product Features
- 115mm Diameter
- 305mm Focal Length
- 2x Magnification
4. Integrally Mounted Inspection Microscope - Model 7000-1-1
(x20-x40)
5. Integrally Mounted Inspection Microscope - Model 7000-1-24. Integrally Mounted Inspection Microscope - Model 7000-1-1
(x20-x40)
(x5 and x10)
![]() |
Model 7000-1-1 |
6. Integrally Mounted Cold Light Source and Magnifying Glass - Model 5100-1-3
![]() |
Model 5100-1-3 |
Product Description
A magnifying glass for general global slices offering approximately 1.5x magnification. Integral cold light powered directly via the Model 51-mz Vibrating.
Upgrade Kit for 5100mz - Model 5100-1-45
Optional kit to upgrade the 5100mz to the 5100mz-Plus. Allowing the user to optimately calibrate the Z-axis deflection of the blade to 2± 0.1µm.
![]() |
Model 5100-1-45 |
Consumables
1. Ceramic Blades - Model 7550-1-C
Product Description
The new blade holder design is now included with all Integraslice and Vibroslice instruments. 7550-1-C and 7550-1-SS are designed for new Integraslice instruments.
Product Features
- Made from ultra hard zirconium
- Honed by a process of "lapping" both sides of the single bevel to micron flatness
- Great rigidity, hence a straight cutting edge
- Prolonged slice life, especially in the most difficult of tissues such as young brain or very old brain
- Inert and impervious to corrosion
- Initial higher cost is offset by its longevity
- Fits into a special blade holder now standard on both Integraslice and Vibroslice instruments
![]() |
Model 7550-1-C |
2. Stainless Steel Blades - Model 7550-1-SS
Product Features
- Double beveled on both faces, honed to an acute cutting edge and hardened to 56 Rockwell.
- Nevertheless, stainless steel is relatively soft and these blades are usually used once or at a maximum changed every day.
- These blades are for use in specially designed blade holders for Vibroslice instruments manufactured prior to 2003.
![]() |
Model 7550-1-SS |
Blade Specifications
EMS7550-1-C | EMS7550-1-SS | |
Material | Ceramic | Stainless Steel |
Dimensions | 38mm x 7mm x 0.5mm | 38mm x 9mm x 0.5mm |
Geometry | Single sided | Double sided |
Bevel | Single bevel | Double bevel |
Honing | Lapped edge | Ground edge |
Packaging | 5 per pack | 50 per pack |
Code | Title | Style | Pack Size | Availability | Price | |
---|---|---|---|---|---|---|
EMS5100MZ | Vibrating microtome, 115V or 220V | 5100mz | Each | No ETA | Quote only | Quote |
EMS5100MZ-PLUS | Vibrating microtome, 115V or 220V | 5100mz-Plus | Each | No ETA | Quote only | Quote |
EMS7000smz-2 | Vibrating microtome, 115V or 220V | 7000smz-2 | Each | No ETA | Quote only | Quote |
Code | Title | Style | Pack Size | Availability | Price | |
---|---|---|---|---|---|---|
EMS5100MZ | Vibrating microtome, 115V or 220V | 5100mz | Each | No ETA | Quote only | Quote |
EMS5100MZ-PLUS | Vibrating microtome, 115V or 220V | 5100mz-Plus | Each | No ETA | Quote only | Quote |
EMS7000smz-2 | Vibrating microtome, 115V or 220V | 7000smz-2 | Each | No ETA | Quote only | Quote |